Step 1

Torque the compression needle to 2.5 in-lb by turning it clockwise using the compression needle driver (PN: 398-01-362). This will place it in the lockout position.

img/help/page3093-J4V7/IMG_0697 copy.jpg
img/help/page3093-J4V7/IMG_0512 copy.jpg
img/help/page3093-J4V7/IMG_0691 copy-m.jpg

Step 2

Sub-assemble the Top Cap interface parts. Place the Torsion Spring, aligning the vertical leg of Torsion Spring, into the hole in the bottom of the Cable Remote Pulley. Align the Pulley Set screw facing the dot opposite to the arrow. Engage the horizontal tang of the torsion spring with the Cable Housing as shown.

img/help/page3093-J4V7/IMG_0691 copy.jpg
img/help/page3093-J4V7/IMG_0692 copy.jpg
img/help/page3093-J4V7/IMG_0693 copy.jpg
img/help/page3093-J4V7/IMG_0694 copy.jpg
img/help/page3093-J4V7/IMG_0694.2 copy.jpg
img/help/page3093-J4V7/IMG_0696-copy.jpg
img/help/page3093-J4V7/IMG_0705 copy-m.jpg

Step 3

Install sub-assy onto Damper facing desired direction for cable routing. 

img/help/page3093-J4V7/IMG_0705 copy.jpg
img/help/page3093-J4V7/IMG_0550 copy.jpg
img/help/page3093-J4V7/IMG_0551 copy-1-m.jpg

Step 4

Rotate the pulley (clockwise) to lock out postion. When rotating the pulley  make sure to clear the damper wrench flats so while rotating the pulley you are turning the comp needle. While holding the pulley and housing in place with downward pressure,  install and tighten the Pulley set screw to 4in/lbs. The pulley should return freely after lockout.

img/help/page3093-J4V7/IMG_0551 copy-1.jpg
img/help/page3093-J4V7/IMG_0709 copy.jpg
img/help/page3093-J4V7/IMG_0552 copy.jpg

GRIP SL Remote Push-to-Unlock

img/help/page3093-J4V7/GRIP-SL-PTU-m.jpg

GRIP SL Remote Push-to-Unlock

img/help/page3093-J4V7/GRIP-SL-PTU.jpg
img/help/page3093-J4V7/IMG_0697.2 copy-m.jpg

Step 1

Torque the compression needle to 2.5 in-lb by turning it clockwise using the compression needle driver (PN: 398-01-362). This will place it in the lockout position.

img/help/page3093-J4V7/IMG_0697.2 copy.jpg
img/help/page3093-J4V7/IMG_0512.2 copy.jpg
img/help/page3093-J4V7/IMG_0710 copy-m.jpg

Step 2

Sub-assemble the Top Cap interface parts. Place the Torsion Spring, aligning the vertical leg of Torsion Spring, into the hole in the bottom of the Cable Remote Pulley. Align the Pulley Set screw facing the dot opposite to the arrow. Engage the horizontal tang of the torsion spring with the Cable Housing.

img/help/page3093-J4V7/IMG_0710 copy.jpg
img/help/page3093-J4V7/IMG_0713 copy.jpg
img/help/page3093-J4V7/IMG_0712 copy.jpg
img/help/page3093-J4V7/IMG_0714 copy.jpg
img/help/page3093-J4V7/IMG_0545 copy-m.jpg

Step 3

Install sub-assy onto Damper facing desired direction for cable routing. 

img/help/page3093-J4V7/IMG_0545 copy.jpg
img/help/page3093-J4V7/IMG_0546 copy-m.jpg

Step 4

Rotate only Cable Pulley 270° CW (Clockwise) to preload Torsion Spring. Check cable direction. When locked out, check that Pulley Set Screw is alingned to Mark. Torque screw to 4in/lbs while holding Pulley. Pulley must return freely after unlock.

img/help/page3093-J4V7/IMG_0546 copy.jpg
img/help/page3093-J4V7/IMG_0547 copy.jpg
img/help/page3093-J4V7/IMG_0722 copy.jpg